Certified BMS Engineer
A fast-paced professional engineering certification designed for mechanical, electrical, and instrumentation graduates to become field-ready BMS testing, commissioning, and facility management engineers.

Key Engineering Competencies Acquired
DDC Point Verification & Site Acceptance Testing (SAT) Procedures
AHU Cascade Temperature & Enthalpy Economizer Control Logic
RS-485 Modbus Energy Meter Loop Integration & Baud Rate Debugging
Dynamic BMS Supervisory Graphics, Alarm Configuration & Trending
Detailed Syllabus Curriculum
Every module combines electrical engineering theory with mandatory physical bench wiring and PLC debug time.
1Module 1: DDC Hardware Wiring & Point Testing
- DDC input/output terminals, resistance measurement for passive temperature sensors
- Active 0-10V / 4-20mA sensor loop verification with multi-meters and loop calibrators
- Digital input dry contact vs. wet contact monitoring, relay interlocks for fan/pump status
- Motorized valve calibration: span adjustment, direction of rotation (direct/reverse acting)
2Module 2: HVAC Control Sequences & Loop Tuning
- Air handling unit sequence of operations: Freeze-stat interlock, fan status, filter dirty switch
- Proportional-Integral (PI) loop tuning for supply air temperature regulation
- Cooling tower fan speed modulation based on condenser water supply temperature
- Water-side economizer cycle control and thermal energy storage tracking
3Module 3: Multi-Protocol Field Bus Integration
- BACnet MS/TP daisy-chain wiring: 120-ohm termination resistors, bias resistors, shield grounding
- Modbus RTU address mapping for electronic energy meters and variable speed drives
- Protocol gateways: Integrating proprietary chiller communication cards into standard BACnet
4Module 4: Supervisory Control & Commissioning Handover
- Point-to-point pre-commissioning checklists and punch list closeouts
- Building management supervisory workstation graphics, dynamic text, and animated fan icons
- Trend logging configuration for historical temperature, humidity, and energy compliance
MANDATORY INDUSTRY CAPSTONE PROJECT
Production Commissioning Benchmark
Automated Air Handling Unit (AHU) commissioning bench: wiring DDC inputs/outputs, programming cooling coil modulation, establishing BACnet supervisory connectivity, and tuning PI control loops.
Program Credentials
Certified BMS Engineer
Duration8 Weeks (Full-Time or Weekend)
Track LevelProfessional Certification
CertificationTechnotiq Certified
Dedicated Hardware Rig
Schneider Electric BACnet DDC Controllers, Belimo 0-10V Actuators, Room Thermostats, Power Transducers
Industry Software
EcoStruxure Building Operation, Niagara Workbench, Modbus Poll, Wireshark
Flexible weekday and weekend batches available with 100% lab access.