Certified BMS Engineer

A fast-paced professional engineering certification designed for mechanical, electrical, and instrumentation graduates to become field-ready BMS testing, commissioning, and facility management engineers.

Certified BMS Engineer

Key Engineering Competencies Acquired

DDC Point Verification & Site Acceptance Testing (SAT) Procedures
AHU Cascade Temperature & Enthalpy Economizer Control Logic
RS-485 Modbus Energy Meter Loop Integration & Baud Rate Debugging
Dynamic BMS Supervisory Graphics, Alarm Configuration & Trending

Detailed Syllabus Curriculum

Every module combines electrical engineering theory with mandatory physical bench wiring and PLC debug time.

1Module 1: DDC Hardware Wiring & Point Testing

  • DDC input/output terminals, resistance measurement for passive temperature sensors
  • Active 0-10V / 4-20mA sensor loop verification with multi-meters and loop calibrators
  • Digital input dry contact vs. wet contact monitoring, relay interlocks for fan/pump status
  • Motorized valve calibration: span adjustment, direction of rotation (direct/reverse acting)

2Module 2: HVAC Control Sequences & Loop Tuning

  • Air handling unit sequence of operations: Freeze-stat interlock, fan status, filter dirty switch
  • Proportional-Integral (PI) loop tuning for supply air temperature regulation
  • Cooling tower fan speed modulation based on condenser water supply temperature
  • Water-side economizer cycle control and thermal energy storage tracking

3Module 3: Multi-Protocol Field Bus Integration

  • BACnet MS/TP daisy-chain wiring: 120-ohm termination resistors, bias resistors, shield grounding
  • Modbus RTU address mapping for electronic energy meters and variable speed drives
  • Protocol gateways: Integrating proprietary chiller communication cards into standard BACnet

4Module 4: Supervisory Control & Commissioning Handover

  • Point-to-point pre-commissioning checklists and punch list closeouts
  • Building management supervisory workstation graphics, dynamic text, and animated fan icons
  • Trend logging configuration for historical temperature, humidity, and energy compliance
MANDATORY INDUSTRY CAPSTONE PROJECT

Production Commissioning Benchmark

Automated Air Handling Unit (AHU) commissioning bench: wiring DDC inputs/outputs, programming cooling coil modulation, establishing BACnet supervisory connectivity, and tuning PI control loops.

Program Credentials

Certified BMS Engineer

Duration8 Weeks (Full-Time or Weekend)
Track LevelProfessional Certification
CertificationTechnotiq Certified
Dedicated Hardware Rig

Schneider Electric BACnet DDC Controllers, Belimo 0-10V Actuators, Room Thermostats, Power Transducers

Industry Software

EcoStruxure Building Operation, Niagara Workbench, Modbus Poll, Wireshark

Flexible weekday and weekend batches available with 100% lab access.