Diploma In Building Management System
The master diploma for modern smart infrastructure. Learn how to automate central chiller plants, air handlers, energy sub-metering, and smoke management systems for commercial towers, IT parks, airports, and healthcare campuses.

Key Engineering Competencies Acquired
Detailed Syllabus Curriculum
Every module combines electrical engineering theory with mandatory physical bench wiring and PLC debug time.
1Module 1: Commercial HVAC Systems & Thermal Engineering
- Fundamentals of commercial refrigeration cycles, chillers (water-cooled vs. air-cooled)
- Chilled water distribution: Primary-only variable flow vs. primary-secondary pumping loops
- Air Handling Units (AHUs), fan coil units (FCUs), and variable air volume (VAV) boxes
- Indoor air quality (IAQ) parameters: temperature, relative humidity, CO2 levels, and static pressure
2Module 2: Direct Digital Controllers (DDC) & Field Instruments
- DDC controller hardware architecture, power supply, and point types (UI, DI, AO, DO)
- Field sensors: immersion temperature, duct humidity, water flow meters, differential pressure switches
- Control actuators: 0-10V / 4-20mA motorized valves, spring-return damper actuators
- Wiring practices, cable shielding, ground loop prevention, and 24VAC transformer sizing
3Module 3: BACnet & Field Network Integration
- BACnet protocol architecture: BACnet IP over Ethernet vs. BACnet MS/TP over RS-485
- Device instance numbers, MAC addressing, baud rate matching, and network routers
- Modbus RTU integration of multi-function energy meters, VFD drives, and generators
- Using BACnet network analyzers for packet capture, token-ring troubleshooting, and point discovery
4Module 4: BMS Supervisory Software & Energy Analytics
- BMS front-end architecture: Graphics development, equipment mimics, and 3D floor plans
- Time-of-Day (TOD) scheduling, holiday calendars, and night setback energy conservation modes
- Alarm routing, priority levels, audio-visual notification, and SMS/email escalation
- Energy metering dashboards, kW/ton chiller efficiency calculations, and sustainability reporting
5Module 5: Fire Alarm & Life Safety Interlocks
- Interface between fire alarm control panels (FACP) and BMS
- Smoke evacuation sequence, stairwell pressurization fans, and fire damper release
- Critical hospital operating theatre positive pressure regulation and isolation room controls
Production Commissioning Benchmark
Full turnkey commissioning of a 5-story commercial building BMS simulator: chilled water plant lead-lag staging, VAV air distribution control, energy meter integration, and supervisory graphics in Niagara.
Diploma In Building Management System
Honeywell BACnet DDC Controllers, Schneider Belimo 0-10V Valve Actuators, Multi-Function Power Meters, Chilled Water Sensors
Honeywell CARE / WEBs-N4, Niagara Framework, Schneider EcoStruxure Building Operation, BACnet Analyzer
Flexible weekday and weekend batches available with 100% lab access.
